Injection quill

Spare part

Introduces a chemical or water stream into the process line ahead of an electrostatic coalescer, prewash coalescer or desalter mixing valve: demulsifier or wash water on a crude oil unit, wash water or a treating solution on a kerosene unit. The quill places the injection point in the centre of the flow so that the additive disperses instead of running along the pipe wall, and its tip is shaped to promote mixing without eroding the pipe opposite.

SKU
AH-EC-1007
Condition
New
Status
Made to order
Indicative lead time
2–4 weeks

Add to enquiry: Injection quill

Why injection quills are replaced

Quills fail by erosion or corrosion of the tip, cracking at the weld between quill and flange, or blockage when the injected chemical is left standing in the line. A quill that has lost its tip injects against the pipe wall, which shows up as poor demulsifier or wash water performance long before the quill itself is suspected. Replacing the quill and reviewing the injection point together usually restores the mixing that the desalter or coalescer was designed for.

Fit and interchange

Compatibility

Matched to the line size, flange rating, insertion length and the fluid being injected, from the piping isometric or a photo of the existing quill and its connection. Retractable and fixed patterns, with or without an isolation valve and check valve, are supplied to suit the existing tapping. Material is selected for the process fluid and the injected chemical.

Design data

Specification

Specification
PropertyValue
Design pressure45 barg
Design temperature, minimum150 °C

Materials of construction

Materials

Materials
ComponentMaterialSpecification / grade
BodyCarbon Steel/Stainless Steel
FlangeCarbon Steel/Stainless Steel

Compliance

Standards and documentation

Documentation available with supply

  • EN 10204 3.1 material test certificate
  • Certificate of conformity
  • Pressure test certificate
  • Dimensional inspection report

Information on this page is indicative. Final suitability and compatibility must be confirmed against your equipment, its serial or tag data and its operating conditions before order. Lead-time bands are indicative and are confirmed at quotation.

Only have a nameplate photo, a tag number or a drawing reference?

That is enough to start. Send what you have for a desalter, dehydrator, electrostatic coalescer or hydrogen adsorption unit, whoever built it, and we will identify the equipment and the parts it needs. Final compatibility is always confirmed against your equipment data and operating conditions.